Search results for "Partial volume"
showing 7 items of 7 documents
Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods
2015
Arterial spin labeling (ASL) is an emerging MRI technique for non-invasive measurement of cerebral blood flow (CBF). Compared to invasive perfusion imaging modalities, ASL suffers from low sensitivity due to poor signal-to-noise ratio (SNR), susceptibility to motion artifacts and low spatial resolution, all of which limit its reliability. In this work, the effects of various state of the art image processing techniques for addressing these ASL limitations are investigated. A processing pipeline consisting of motion correction, ASL motion correction imprecision removal, temporal and spatial filtering, partial volume effect correction, and CBF quantification was developed and assessed. To fur…
Partial volume correction for volume estimation of liver metastases and lymph nodes in CT scans using spatial subdivision
2010
In oncological therapy monitoring, the estimation of tumor growth from consecutive CT scans is an important aspect in deciding whether the given treatment is adequate for the patient. This can be done by measuring and comparing the volume of a lesion in the scans based on a segmentation. However, simply counting the voxels within the segmentation mask can lead to significant differences in the volume, if the lesion has been segmented slightly differently by various readers or in different scans, due to the limited spatial resolution of CT and due to partial volume effects. We present a novel algorithm for measuring the volume of liver metastases and lymph nodes which considers partial volum…
Small animal tumour imaging with MRI and the ECAT EXACT scanner: application of partial volume correction and comparison with microPET data.
2010
Objective Partial volume effects caused by limited spatial resolution of conventional positron emission tomography (PET) scanners result in an underestimation of the activity concentration in small tumours. The aim of the study was to evaluate the feasibility of small animal tumour imaging with the clinical PET scanner ECAT EXACT after partial volume correction based on MRI calculations. The same tumour model was examined additionally with the small animal PET system, microPET focus 120. Methods Before the ECAT EXACT studies recovery coefficients for different sphere volumes were generated with phantom experiments. For the following in-vivo study DS-sarcoma cells were implanted on both hind…
Association between Cognitive Performance and Cortical Glucose Metabolism in Patients with Mild Alzheimer’s Disease
2004
<i>Background:</i> Neuronal and synaptic function in Alzheimer’s disease (AD) is measured in vivo by glucose metabolism using positron emission tomography (PET). <i>Objective:</i> We hypothesized that neuronal activation as measured by PET is a more sensitive index of neuronal dysfunction than activity during rest. We investigated if the correlations between dementia severity as measured with the Mini Mental State Examination (MMSE) and glucose metabolism are an artifact of brain atrophy. <i>Method:</i> Glucose metabolism was measured using [<sup>18</sup>F]fluorodeoxyglucose PET during rest and activation due to audiovisual stimulation in 13 m…
Metabolic impact of Partial Volume Correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment
2014
AIM: The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. METHODS: Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-I) and after (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated f…
Hybrid segmentation and exploration of the human lungs
2004
Segmentation of the tracheo-bronchial tree of the lungs is notoriously difficult. This is due to the fact that the small size of some of the anatomical structures is subject to partial volume effects. Furthermore, the limited intensity contrast between the participating materials (air, blood, and tissue) increases the segmentation of difficulties. In this paper, we propose a hybrid segmentation method which is based on a pipeline of three segmentation stages to extract the lower airways down to the seventh generation of the bronchi. User interaction is limited to the specification of a seed point inside the easily detectable trachea at the upper end of the lower airways. Similarly, the comp…
Right ventricular volume determination in isolated human hearts
1986
For right ventricular volume determination a new method was developed that took into account right ventricular imaging by apical two-dimensional echocardiography in the four- and two-chamber views. Right ventricular volume was calculated by subtraction of the partial volume of the left ventricle and interventricular septum from the total heart volume of the right and left ventricles including the interventricular septum. Accuracy of the subtraction method was evaluated in isolated human hearts by two-dimensional echocardiography and radiography. Regression analysis indicated that for both the echocardiographic and radiologic procedures, the subtraction method gave the best correlation with …